Search Results/Filters    

Filters

Year

Banks




Expert Group











Full-Text


Issue Info: 
  • Year: 

    2022
  • Volume: 

    52
  • Issue: 

    1
  • Pages: 

    33-41
Measures: 
  • Citations: 

    0
  • Views: 

    117
  • Downloads: 

    28
Abstract: 

This paper proposes a 2.4 GHz active mixer without passive inductor for the transceiver system. Taking into account the design requirements of the mixer, a double-balanced down-conversion structure with active inductor and negative resistance is designed. The proposed mixer with 130 nm CMOS technology is designed and simulated using Cadence software at 1.5 V supply voltage. Although we had to compromise conversion gain with linearity, we were able to achieve very High conversion gain with average linearity. Based on the results of post-layout simulations, the conversion gain of 27.57 dB, IIP3 equal to -7.88 dBm, 1-dB compression point equal to -17.34 dBm and IIP2 equal to 44.22 dBm with power consumption of 2.5 mW was obtained for the proposed mixer. The chip size without input and output pads is 95.18 µm × 117.68 µm, which leads to a chip area of 0.0112mm2.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 117

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 28 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2011
  • Volume: 

    6
  • Issue: 

    5 (SPECIAL ISSUE)
  • Pages: 

    519-525
Measures: 
  • Citations: 

    0
  • Views: 

    1149
  • Downloads: 

    0
Abstract: 

Introduction: Usually osseointegration takes between three to six months after implant placement but patients are interested to have early loading. There are no definitive criteria for measuring bone mineral density (BMD), insertion torque (IT) (final torque force) and resonance frequency analysis (RFA) (primary implant stability) to determine exact loading time based on the relationship between the above-mentioned parameters. The aim of this study was to determine the relationship between IT, RFA and BMD in screw-type implants.Materials and Methods: This clinical trial was conducted on 18 patients who were candidates for ITI implant placement. Written consent was taken and jaw bone density was determined via a digital radiography technique before surgery. After implant placement, RFA and IT were measured. Fifty-five ITI implants of the total 62 implants placed were evaluated; the implants were 12 mm long with a diameter of 4.1 mm. Data was analyzed with Pearson’s test using SPSS.15 software (a=0.05).Results: There was a significant relationship between IT, RFA and BMD. Pearson’s test showed a correlation coefficient of 0.872 to 0.789 between the three parameters, indicating a strong relationship between them. The mean bone density was 1.468±0.042 g/cm2; the mean RFA was 66.01±2.2 ISQ and the mean IT was 34.62±3.33 N/cm2.Conclusion: Based on the results of the present study there is a significant relationship between, IT, RFA and BMD (p value=0.001).

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 1149

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 10
Author(s): 

BOLLERSLEV T. | WRIGHT J.H.

Issue Info: 
  • Year: 

    2001
  • Volume: 

    83
  • Issue: 

    -
  • Pages: 

    596-602
Measures: 
  • Citations: 

    2
  • Views: 

    198
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 198

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 2 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

SULAIMAN A.H.

Issue Info: 
  • Year: 

    2015
  • Volume: 

    11
  • Issue: 

    2
  • Pages: 

    104-109
Measures: 
  • Citations: 

    1
  • Views: 

    106
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 106

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

Issue Info: 
  • Year: 

    0
  • Volume: 

    10
  • Issue: 

    40
  • Pages: 

    149-162
Measures: 
  • Citations: 

    1
  • Views: 

    235
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 235

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2018
  • Volume: 

    20
  • Issue: 

    10 (127)
  • Pages: 

    20-28
Measures: 
  • Citations: 

    0
  • Views: 

    854
  • Downloads: 

    0
Abstract: 

Background: Tympanometry is one of the most important audio logical tests for the assessment of neonatal hearing screening programs. This test is usually done using a 226 Hertz probe tone; however, in infants less than 6 months of age, using this probe tone frequency is not reliable due to the different characteristics of the middle ear compared to adults. The purpose of this study was to assess the obtained tympanometric data in neonates 1 to 14 days with normal hearing using 226, 678, 800 and 1000 Hertz frequency probes tones.Materials and Methods: In this cross-sectional study, 30 neonates aged 1 to 14 days who were diagnosed as normal in hearing aspect with using otoacoustic emissions test, were assessed by tympanometry. Tympanometric tests were performed using 226, 678, 800 and 1000 Hertz frequency probe tones for both ears. For data analysis, the T-paired method has been used.Results: With using 226 Hertz frequency probe tone, incidence of unusual double peak tympanograms was observed in 65% of cases, which with increasing frequency of the probe tone, this percentage was decreased. There was also a statistically significant difference between the static admittance peak compensated in two 226 and 1000 Hertz frequency probes tones.Conclusion: In neonates with normal hearing and without any risk factors for hearing loss, the 1000-Hertz Tympanogram shows a better middle ear status than the 226-Hertz tympanogram.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 854

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2012
  • Volume: 

    15
  • Issue: 

    2 (60)
  • Pages: 

    47-49
Measures: 
  • Citations: 

    0
  • Views: 

    254
  • Downloads: 

    129
Abstract: 

Background: Systemic sclerosis is an autoimmune connective tissue disorder which is characterised by cutaneous and internal organ fibrosis. Raynaud’s phenomenon is the earliest feature and may precede the onset of the disease by months to years. The heart, lungs, gastrointestinal tract, kidneys and other organs may be involved. Our aim was to evaluate skin thickness and echogenicity in systemic sclerosis patients by ultrasound and compare it with the healthy age and sex matched controls.Method: Our study included 15 successively admitted patients (14 females and 1 male) with systemic sclerosis and 15 healthy age and sex matched controls. All the patients met the ACR criteria of diagnosis. The age range of the patients was 25-55 years. The disease duration ranged from 1-8 years. A complete history and physical examination was done for each patient. Skin thickness and echogenicity were measured by a 20MHz ultrasound probe at 6 different anatomical sites which was compared with that of the controls.Result: Skin thickness was more in systemic sclerosis patients (significant p value) as compared to controls, and echogenicity was inversely proportional to the skin thickness.Conclusion: Skin ultrasonography is a noninvasive method which can reflect the severity of skin involvement and periodic assessment of skin thickness and echogenicity can help to monitor the progression of the disease.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 254

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 129 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2016
  • Volume: 

    3
Measures: 
  • Views: 

    174
  • Downloads: 

    107
Abstract: 

HYPERICUM PERFORATUM (ST. JOHN’S WORT) IS PERENNIAL HERB, WHICH CONSUMED WORLDWIDE AS ITS MEDICINAL PROPERTIES. IN THIS PLANT ACHIEVING HOMOGENEITY IN PLANT MATERIAL IS ONE OF THE MOST IMPORTANT BREEDING OBJECTIVES. ONE WAY TO ACHIEVE THESE GOALS IS SOMATIC EMBRYOGENESIS. IN THIS REGARDS, PETIOLE AND LEAF EXPLANTS OF ST. JOHN’S WORT WERE CULTURED IN MS MEDIUM SUPPLEMENTED WITH DIFFERENT CONCENTRATIONS OF 2, 4-D (0, 0.5, 1 AND 2 MG/L) AND KIN (0, 0.5, 1.5 AND 2MG/L) TO PRODUCED EMBRYONIC CALLUS. AFTER 4 WEEKS, THE PRODUCED CALLUS WAS TRANSFERRED TO MS MEDIUM SUPPLEMENTED WITH NAA (0, 1 AND 2 MG/L) AND BAP (0, 1 AND 2 MG/L) FOR SOMATIC EMBRYO PRODUCTION. THE RESULTS SHOWED THAT THE HighEST EMBRYONIC CALLUS WERE PRODUCED WITH PETIOLE EXPLANT AT MS MEDIUM SUPPLEMENTED WITH 1MG/L 2, 4-D AND 1.5 MG/L KIN. THE HighEST SOMATIC EMBRYOS OBTAINED WITH PETIOLE EXPLANT IN MS MEDIUM SUPPLEMENTED WITH 1MG/L NAA AND 1 MG/L BAP.

Yearly Impact:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 174

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 107
Issue Info: 
  • Year: 

    0
  • Volume: 

    -
  • Issue: 

    3
  • Pages: 

    171-174
Measures: 
  • Citations: 

    1
  • Views: 

    364
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 364

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2025
  • Volume: 

    21
  • Issue: 

    2
  • Pages: 

    3640-3640
Measures: 
  • Citations: 

    0
  • Views: 

    9
  • Downloads: 

    0
Abstract: 

The development of advanced diagnostic tools is critical for the effective monitoring and management of electrical insulation systems. This paper presents the development of an Ultra High frequency (UHF) sensor designed for the detection of partial discharges (PD) within High-voltage substations. The study focuses on the sensor’s technical development, encompassing design considerations, fabrication processes, and initial performance evaluations in laboratory settings. The engineering principles underlying the sensor design are detailed, including the selection of innovative materials that enhance sensitivity and frequency response. The sensor configuration is tailored to optimize the detection of PD signals, with adjustments made based on simulated PD scenarios. Initial testing results demonstrate the sensor’s capability to detect a range of PD activities, showcasing its potential effectiveness in real-world applications. The sensor's performance is analyzed through a series of controlled lab experiments, which confirm its High sensitivity and broad operational frequency range. This paper not only illustrates the technical specifications and capabilities of the newly developed UHF sensor but also discusses its practical implications for improving the reliability and efficiency of PD monitoring systems in electrical substations.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 9

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button